An Improved Sliding-Load Calibration Procedure Using an Semiparametric Circle-Fitting Procedure

Research output: Contribution to journalArticlepeer-review

12 Citations (Scopus)

Abstract

Circle-fitting problems often occur in microwave engineering when dealing with variable delays, e.g., during calibration using a sliding load. This paper proposes an efficient semiparametric circle-fitting procedure, which takes into account the phase relationships over the frequenties. It produces more accurate results than the standard slicing-load calibration, requires only three positions on the sliding load for the whole frequency band, and is more robust to the settings of the positions of the sliding load. The proposed method also has the ability to detect whether or not the sliding load is defective or out of its specifications. This can be done by using only three positions on the sliding load. Optimal-position settings are then proposed. The performance of the proposed method is illustrated on sliding-load measurements up to 50 GHz, demonstrating the ability of detecting modeling errors and showing that the accuracy of the proposed method using three positions is comparable to the standard method with six positions.
Original languageEnglish
Pages (from-to)1027-1033
Number of pages7
JournalIEEE Transactions on Microwave Theory and Techniques
Volume45
Issue number7
Publication statusPublished - 1 Jul 1997

Keywords

  • Calibration
  • Delay
  • Frequency dependence
  • Frequency measurement
  • Impedance measurement
  • Measurement standards
  • Parametric statistics
  • Position measurement
  • Reflection
  • Transmission line measurements

Fingerprint

Dive into the research topics of 'An Improved Sliding-Load Calibration Procedure Using an Semiparametric Circle-Fitting Procedure'. Together they form a unique fingerprint.

Cite this