Abstract
This paper aims to assess the lifetime of a T-type active front end (AFE) converter in the context of Grid-to-Vehicle (G2V) and Vehicle-to-Grid (V2G) applications providing various grid services. To achieve this goal, the research paper presents two G2V and three V2G profiles and measures the junction temperature oscillations
for the entire mission profile. Then, the temperature profiles are imported into a reliability assessment model to determine each mission profile’s impact on the system’s reliability
for the entire mission profile. Then, the temperature profiles are imported into a reliability assessment model to determine each mission profile’s impact on the system’s reliability
Original language | English |
---|---|
Title of host publication | IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society |
Place of Publication | Singapore |
Publisher | IEEE |
Pages | 1-7 |
Number of pages | 7 |
ISBN (Electronic) | 979-8-3503-3182-0 |
ISBN (Print) | 979-8-3503-3183-7 |
DOIs | |
Publication status | Published - 16 Nov 2023 |
Publication series
Name | IECON Proceedings (Industrial Electronics Conference) |
---|---|
ISSN (Print) | 2162-4704 |
ISSN (Electronic) | 2577-1647 |
Bibliographical note
Funding Information:This work was supported by HiEFFICIENT project. This project has received funding from the ECSEL Joint Undertaking (JU) under grant agreement no. 101007281. The JU receives support from the European Union s Horizon 2020 research and innovation programme and Austria, Germany, Slovenia, Netherlands, Belgium, Slovakia, France, Italy, and Turkey.
Funding Information:
Acknowledgments: This work was supported by HiEFFICIENT project. This project has received funding from the ECSEL Joint Undertaking (JU) under grant agreement no. 101007281. The JU receives support from the European Union’s Horizon 2020 research and innovation programme and Austria, Germany, Slovenia, Netherlands, Belgium, Slovakia, France, Italy, and Turkey.
Publisher Copyright:
© 2023 IEEE.