Skip to main navigation Skip to search Skip to main content

Can a Commercially Available Smartwatch Device Accurately Measure Nighttime Sleep Outcomes in Individuals with Knee Osteoarthritis and Comorbid Insomnia? A Comparison with Home-Based Polysomnography

Research output: Contribution to journal › Article › peer-review

6 Downloads (Pure)

Abstract

Highlights: What are the main findings? Fitbit Sense demonstrates high accuracy and sensitivity for detecting sleep in individuals with knee osteoarthritis and insomnia. The device shows limited ability to differentiate quiet wakefulness from sleep and less precision in classifying specific sleep stages. What is the implication of the main finding? Fitbit Sense can be a useful complementary tool for monitoring general sleep duration, timing, and regularity in this population. Sleep stage and fragmentation data should be interpreted with caution, as agreement with polysomnography decreases under more disrupted sleep conditions. Sleep is a vital physiological process for recovery and health. In people with knee osteoarthritis (OA), disrupted sleep is common and linked to worse clinical outcomes. Commercial sleep trackers provide an accessible option to monitor sleep in this population, but their accuracy for detecting sleep, wake, and sleep stages remains uncertain. This study compared nighttime sleep data from polysomnography (PSG) and Fitbit Sense in individuals with knee OA and insomnia. Data were collected from 53 participants (60.4% women, mean age 51 ± 8.2 years) over 62 nights using simultaneous PSG and Fitbit recording. Fitbit Sense showed high accuracy (85.76%) and sensitivity (95.95%) for detecting sleep but lower specificity (50.96%), indicating difficulty separating quiet wakefulness from sleep. Agreement with PSG was higher on nights with longer total sleep time, higher sleep efficiency, shorter sleep onset, and fewer awakenings, suggesting better performance when sleep is less fragmented. The device showed limited precision in classifying sleep stages, often misclassifying deep and REM sleep as light sleep. Despite these issues, Fitbit Sense may serve as a useful complementary tool for monitoring sleep duration, timing, and regularity in this population. However, sleep stage and fragmentation data should be interpreted cautiously in both clinical and research settings.

Original languageEnglish
Article number4813
Pages (from-to)1-22
Number of pages22
JournalSensors (Basel, Switzerland)
Volume25
Issue number15
DOIs
Publication statusPublished - 5 Aug 2025

Bibliographical note

Publisher Copyright:
© 2025 by the authors.

Keywords

  • Humans
  • Female
  • Polysomnography/methods
  • Middle Aged
  • Male
  • Osteoarthritis, Knee/physiopathology
  • Sleep Initiation and Maintenance Disorders/physiopathology
  • Sleep/physiology
  • Adult
  • Wearable Electronic Devices
  • Sleep Stages/physiology
  • Aged

Fingerprint

Dive into the research topics of 'Can a Commercially Available Smartwatch Device Accurately Measure Nighttime Sleep Outcomes in Individuals with Knee Osteoarthritis and Comorbid Insomnia? A Comparison with Home-Based Polysomnography'. Together they form a unique fingerprint.

Cite this