T1 - Comparison between the novel diamond temp and the classical 8-mm tip ablation catheters in the setting of typical atrial flutter
AU - Ramak, Robbert
AU - Lipartiti, Felicia
AU - Mojica, Joerelle
AU - Monaco, Cinzia
AU - Bisignani, Antonio
AU - Eltsov, Ivan
AU - Sorgente, Antonio
AU - Capulzini, Lucio
AU - Paparella, Gaetano
AU - Deruyter, Bernard
AU - Iacopino, Saverio
AU - Motoc, Andreea Iulia
AU - Luchian, Maria Luiza
AU - Osorio, Thiago Guimaraes
AU - Overeinder, Ingrid
AU - Bala, Gezim
AU - Almorad, Alexandre
AU - Ströker, Erwin
AU - Sieira, Juan
AU - Jordaens, Luc
AU - Brugada, Pedro
AU - de Asmundis, Carlo
AU - Chierchia, Gian-Battista
N1 - © 2022. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2022/9
Y1 - 2022/9
N2 - PURPOSE: Radiofrequency (RF) catheter ablation is widely accepted as a first-line therapy for cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). The novel DiamondTemp (DT) catheter with temperature feedback during RF ablation has been released recently on the market. The purpose of this study was to evaluate the impact of DiamondTemp (DT) technology on ablation efficiency during AFL.METHODS: In this single-center study, 30 consecutive patients with typical AFL indicated to ablation of CTI were included. The first 15 patients underwent CTI ablation using 8-mm tip catheter, and the following 15 patients underwent temperature-controlled RF ablation using DT catheter. The endpoints were number and mean total duration of RF applications, mean temperature reached in the setting of CTI, procedural times, and fluoroscopy times.RESULTS: There were no significant differences between the two groups concerning baseline characteristics. Mean duration of the each application (71.5 s ± 30.6 vs 12.4 s ± 13.2, p value < 0.001), mean total duration of RF applications (517,73 s ± 377,96 vs 112,8 s ± 43,58; p value < 0.001), procedural times (51.6 min ± 24.2 vs 38.6 ± 8.2; p = 0.03), and fluoroscopy times (16.2 min ± 10.2 vs 8 min ± 4.24; p = 0.005) were longer in the 8-mm ablation catheter group. Mean temperature measurements (51.9 °C ± 3.59 vs 56.7 °C ± 3.34, p value < 0.003) were as well lower in the 8-mm ablation catheter group.CONCLUSIONS: Catheter ablation of CTI-dependent AFL by means of DT resulted in a significant reduction of total and single application RF delivery time, procedure, and fluoroscopy times.
AB - PURPOSE: Radiofrequency (RF) catheter ablation is widely accepted as a first-line therapy for cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL). The novel DiamondTemp (DT) catheter with temperature feedback during RF ablation has been released recently on the market. The purpose of this study was to evaluate the impact of DiamondTemp (DT) technology on ablation efficiency during AFL.METHODS: In this single-center study, 30 consecutive patients with typical AFL indicated to ablation of CTI were included. The first 15 patients underwent CTI ablation using 8-mm tip catheter, and the following 15 patients underwent temperature-controlled RF ablation using DT catheter. The endpoints were number and mean total duration of RF applications, mean temperature reached in the setting of CTI, procedural times, and fluoroscopy times.RESULTS: There were no significant differences between the two groups concerning baseline characteristics. Mean duration of the each application (71.5 s ± 30.6 vs 12.4 s ± 13.2, p value < 0.001), mean total duration of RF applications (517,73 s ± 377,96 vs 112,8 s ± 43,58; p value < 0.001), procedural times (51.6 min ± 24.2 vs 38.6 ± 8.2; p = 0.03), and fluoroscopy times (16.2 min ± 10.2 vs 8 min ± 4.24; p = 0.005) were longer in the 8-mm ablation catheter group. Mean temperature measurements (51.9 °C ± 3.59 vs 56.7 °C ± 3.34, p value < 0.003) were as well lower in the 8-mm ablation catheter group.CONCLUSIONS: Catheter ablation of CTI-dependent AFL by means of DT resulted in a significant reduction of total and single application RF delivery time, procedure, and fluoroscopy times.
KW - 8-mm tip catheter
KW - Cavotricuspid isthmus
KW - DiamondTemp
KW - Radio frequency ablation
KW - Temperature control
KW - Typical atrial flutter
UR - http://www.scopus.com/inward/record.url?scp=85125590687&partnerID=8YFLogxK
U2 - 10.1007/s10840-022-01152-w
DO - 10.1007/s10840-022-01152-w
M3 - Article
C2 - 35239069
VL - 64
SP - 751
EP - 757
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
SN - 1383-875X
IS - 3
ER -