Skip to main navigation Skip to search Skip to main content

Cost-Utility analysis of control-IQ technology relative to conventional insulin therapy in adults with type 1 diabetes

  • Jolien De Meulemeester
  • , Francesca Fiorentino
  • , Nuno Picado
  • , Margaretha M. Visser
  • , Bart Keymeulen
  • , Christophe De Block
  • , Liesbeth Van Huffel
  • , Youri Taes
  • , Dominique Ballaux
  • , Katrien Spincemaille
  • , Joke Marlier
  • , Gerd Vanhaverbeke
  • , Ine Lowyck
  • , Chris Vercammen
  • , Ides M. Colin
  • , Vanessa Preumont
  • , Chantal Mathieu
  • , Jeroen Luyten
  • , Sharon M. Wang
  • , Bimal V. Patel
  • Jordan E. Pinsker, Pieter Gillard

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Objective: This study evaluated the cost utility of the t:slim X2 insulin pump with Control-IQ technology (Control-IQ) relative to multiple daily injections (MDIs) and standard insulin pump therapy, both used in combination with continuous glucose monitoring (CGM), in adults with type 1 diabetes from a payer perspective in Belgium. Research Design and Methods: A lifetime cost–utility analysis was conducted using the IQVIA CORE Diabetes Model. Baseline characteristics and treatment effects were informed by the Belgian real-world, multicenter, prospective INRANGE study. Direct medical costs included treatment, complication management, and severe hypoglycemic events. Country-specific costs were based on RIZIV-INAMI data and other publicly available sources. Utility values were based on published literature and included the reduction in fear of hypoglycemia associated with Control-IQ as reported in the INRANGE study. Outcomes included quality-adjusted life years (QALYs) and incremental cost–utility ratios (ICURs). Scenario analyses explored variations in the comparator (MDI + CGM only), reduced HbA1c efficacy, and time horizon. Results: Control-IQ yielded 19.50 QALYs versus 17.92 for MDI and standard insulin pump therapy plus CGM, with total costs of €193, 588 and €160, 129, respectively, resulting in an ICUR of €21, 111/QALY. Scenario analyses confirmed robustness: MDI + CGM as sole comparator (ICUR: €41, 701/QALY), reduced HbA1c efficacy (ICUR: €25, 967/QALY), and a 20-year time horizon (ICUR: €30, 183/QALY). Conclusions: Control-IQ provides clinical benefits relative to MDI and standard insulin pump therapy plus CGM in adults with type 1 diabetes in Belgium and appears to be cost-effective in this setting, considering commonly used thresholds. These findings support the broader adoption of automated insulin delivery systems in diabetes management.

Original languageEnglish
Pages (from-to)717-728
Number of pages12
JournalDiabetes Technology & Therapeutics
Volume28
Issue number7
Early online date22 Dec 2025
DOIs
Publication statusPublished - 1 Jul 2026

Bibliographical note

Publisher Copyright:
© 2025 Mary Ann Liebert (NY), LLC

Keywords

  • Control-IQ technology
  • Automated insulin delivery
  • Cost-effectiveness
  • Cost-utility analysis
  • Economic evaluation
  • Hybrid closed-loop
  • t:slim X2
  • Type 1 diabetes

Fingerprint

Dive into the research topics of 'Cost-Utility analysis of control-IQ technology relative to conventional insulin therapy in adults with type 1 diabetes'. Together they form a unique fingerprint.

Cite this