Design Investigation of Liquid Cooled Heat Sink for GaN FET Dual-Three Phase Inverter

Research output: Chapter in Book/Report/Conference proceedingConference paperResearch

3 Citations (Scopus)
372 Downloads (Pure)

Abstract

This paper presents the design investigation of liquid cooled heat sinks for a 48V/35 kW GaN FET dual three-phase inverter using CFD analysis. With the use of GaN FETs , higher power density can be realized in power electronics components which results in higher heat density as well. In order to find an optimal heat sink configuration, the cooling performance of two different configurations of cold plates is investigated and compared with commercially available cold plate. And the distribution characteristics of the temperature, pressure and fluid velocity field are compared and analyzed.
Original languageEnglish
Title of host publication2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion
PublisherIEEE
Pages143-148
Number of pages6
ISBN (Electronic)9781665484596
DOIs
Publication statusPublished - 2022
Event2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion: SPEEDAM 2022 - Italy, Sorrento, Italy
Duration: 21 Jun 202225 Jun 2022

Conference

Conference2022 International Symposium on Power Electronics, Electrical Drives, Automation and Motion
Country/TerritoryItaly
CitySorrento
Period21/06/2225/06/22

Fingerprint

Dive into the research topics of 'Design Investigation of Liquid Cooled Heat Sink for GaN FET Dual-Three Phase Inverter'. Together they form a unique fingerprint.

Cite this