Skip to main navigation Skip to search Skip to main content

Geometrical calibration and aperture configuration design in multi-pinhole spect

  • Kathleen Vunckx
  • , Michel Defrise
  • , Dirk Bequé
  • , Christian Van Hove
  • , Andriy Andreyev
  • , Johan Nuyts

Research output: Chapter in Book/Report/Conference proceeding › Conference paper

8 Citations (Scopus)

Abstract

A clinical gamma camera can be converted into a high resolution SPECT system for small animal imaging, by replacing the clinical collimator(s) with pinhole collimators. However, for optimal performance, an accurate geometrical calibration is required. If it is assumed that the detector orbit is a true circle, the calibration requires the determination of seven parameters. It has been shown that these can be uniquely determined from a SPECT scan of a phantom consisting of three point sources, if two of the distances between these point sources are known. For multi-pinhole SPECT, two point sources should be sufficient, knowledge of the distance between the point sources is not required. The calibration method has been extended for cases where the orbit deviates from the ideal circle. A second interesting problem in multipinhole SPECT is the optimisation of the collimator design. This requires a measure of image quality, enabling objective comparison between different designs. An efficient analytical method has been developed for that purpose. With this method, it has been shown that the aperture diameter should be slightly smaller than the desired system resolution. We have also found that increased multiplexing (which comes with an apparent increase in system sensitivity) does not lead to reduced variance for a particular target resolution. In practice, avoiding all overlap seems to yield better performance.
Original languageEnglish
Title of host publication5th IEEE International Symposium on Biomedical Imaging - From Nano to Macro
Pages1403-1406
Number of pages4
Publication statusPublished - May 2008
EventFinds and Results from the Swedish Cyprus Expedition: A Gender Perspective at the Medelhavsmuseet - Stockholm, Sweden
Duration: 21 Sept 2009 → 25 Sept 2009

Publication series

Name5th IEEE International Symposium on Biomedical Imaging - From Nano to Macro

Conference

ConferenceFinds and Results from the Swedish Cyprus Expedition: A Gender Perspective at the Medelhavsmuseet
Country/TerritorySweden
CityStockholm
Period21/09/09 → 25/09/09

Keywords

  • pinhole SPECT
  • microSPECT
  • small animal imaging

Fingerprint

Dive into the research topics of 'Geometrical calibration and aperture configuration design in multi-pinhole spect'. Together they form a unique fingerprint.

Cite this