Normal Reference Ranges for Echocardiography: rationale, study design, and methodology (NORRE Study)

P. Lancellotti, Nico Van De Veire

Research output: Contribution to journalArticlepeer-review

81 Citations (Scopus)

Abstract

Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic reference values, their use for clinical decision-making remains questionable.

The aim of the Normal Reference Ranges for Echocardiography Study (NORRE Study) is to obtain a set of normal values for cardiac chamber geometry and function in a large cohort of healthy Caucasian individuals aged over a wide range of ages (2575 years) using both conventional and advanced echocardiographic techniques.

The NORRE Study is a large prospective, observational multicentre study in which transthoracic echocardiographic studies will be acquired in 22 laboratories accredited by the European Association of Cardiovascular Imaging and in one laboratory in the USA accredited by ICAEL. The final sample size has been estimated in 1100 normal subjects in whom M-mode, 2D, and 3D imaging, colour Doppler, pulsed-wave Doppler, pulsed-wave tissue Doppler, and colour tissue Doppler imaging data will be obtained. All studies will be sent to a central echocardiographic core laboratory for quantitative analysis. Multiple studies will be performed for reproducibility analysis.

After completion of the NORRE Study, uniform reference limits according to age, gender, and anthropometric parameters will be available to standardize the quantitative interpretation of echocardiography.
Original languageEnglish
Pages (from-to)303-308
Number of pages6
JournalEuropean Heart Journal. Cardiovascular Imaging
Volume14
Issue number4
Publication statusPublished - Apr 2013

Keywords

  • M-mode
  • 2D and 3D echocardiography
  • Cardiac mechanics
  • Chamber size and function
  • reference values

Fingerprint

Dive into the research topics of 'Normal Reference Ranges for Echocardiography: rationale, study design, and methodology (NORRE Study)'. Together they form a unique fingerprint.

Cite this