TY - JOUR
T1 - Surface modification of biodegradable Mg alloy by adapting µEDM capabilities with cryogenically-treated tool electrodes
AU - Davis, Rahul
AU - Singh, Abhishek
AU - Debnath, Kishore
AU - Keshri, Anup Kumar
AU - Soares, Paulo
AU - Sopchenski, Luciane
AU - Terryn, Herman A.
AU - Prakash, Ved
N1 - © The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
PY - 2023/6
Y1 - 2023/6
N2 - Biomaterials are engineered to develop an interaction with living cells for therapeutic and diagnostic purposes. The last decade reported a tremendously rising shift in the requirement for miniaturized biomedical implants exhibiting high precision and comprising various biomaterials such as non-biodegradable titanium (Ti) alloys and biodegradable magnesium (Mg) alloys. The excellent mechanical properties and lightweight characteristics of Mg AZ91D alloy make it an emerging material for biomedical applications. In this regard, micro-electric discharge machining (µEDM) is an excellent method that can be used to make micro-components with high dimensional accuracy. In the present research, attempts were made to improve the µEDM capabilities by using cryogenically-treated copper (CTCTE) and brass tool electrodes (CTBTE) amid machining of biodegradable Mg AZ91D alloy, followed by their comparison with a pair of untreated copper (UCTE) and brass tool electrodes (UBTE) in terms of minimum machining-time and dimensional-irregularity. To investigate the possible modification on the surfaces achieved with minimum machining-time and dimensional-irregularity, the morphology, chemistry, micro-hardness, corrosion resistance, topography, and wettability of these surfaces were further examined. The surface produced by CTCTE exhibited the minimum surface micro-cracks and craters, acceptable recast layer thickness (2.6 µm), 17.45% improved micro-hardness, satisfactory corrosion resistance, adequate surface roughness (Ra: 1.08 µm), and suitable hydrophobic behavior (contact angle: 119°), confirming improved biodegradation rate. Additionally, a comparative analysis among the tool electrodes revealed that cryogenically-treated tool electrodes outperformed the untreated ones. CTCTE-induced modification on the Mg AZ91D alloy surface suggests its suitability in biodegradable medical implant applications.
AB - Biomaterials are engineered to develop an interaction with living cells for therapeutic and diagnostic purposes. The last decade reported a tremendously rising shift in the requirement for miniaturized biomedical implants exhibiting high precision and comprising various biomaterials such as non-biodegradable titanium (Ti) alloys and biodegradable magnesium (Mg) alloys. The excellent mechanical properties and lightweight characteristics of Mg AZ91D alloy make it an emerging material for biomedical applications. In this regard, micro-electric discharge machining (µEDM) is an excellent method that can be used to make micro-components with high dimensional accuracy. In the present research, attempts were made to improve the µEDM capabilities by using cryogenically-treated copper (CTCTE) and brass tool electrodes (CTBTE) amid machining of biodegradable Mg AZ91D alloy, followed by their comparison with a pair of untreated copper (UCTE) and brass tool electrodes (UBTE) in terms of minimum machining-time and dimensional-irregularity. To investigate the possible modification on the surfaces achieved with minimum machining-time and dimensional-irregularity, the morphology, chemistry, micro-hardness, corrosion resistance, topography, and wettability of these surfaces were further examined. The surface produced by CTCTE exhibited the minimum surface micro-cracks and craters, acceptable recast layer thickness (2.6 µm), 17.45% improved micro-hardness, satisfactory corrosion resistance, adequate surface roughness (Ra: 1.08 µm), and suitable hydrophobic behavior (contact angle: 119°), confirming improved biodegradation rate. Additionally, a comparative analysis among the tool electrodes revealed that cryogenically-treated tool electrodes outperformed the untreated ones. CTCTE-induced modification on the Mg AZ91D alloy surface suggests its suitability in biodegradable medical implant applications.
KW - Copper and brass tool electrodes
KW - Dimensional-irregularity
KW - Machining-time
KW - Magnesium alloy
KW - Micro-electric discharge machining
KW - Surface modification
UR - http://www.scopus.com/inward/record.url?scp=85153401608&partnerID=8YFLogxK
U2 - 10.1007/s00170-023-11395-0
DO - 10.1007/s00170-023-11395-0
M3 - Article
C2 - 37197058
AN - SCOPUS:85153401608
VL - 126
SP - 4617
EP - 4636
JO - International Journal of Advanced Manufacturing Technology
JF - International Journal of Advanced Manufacturing Technology
SN - 0268-3768
IS - 9-10
ER -