The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients

Francesco Maffessanti, Tomasz Jadczyk, Radosław Kurzelowski, François Regoli, Maria Luce Caputo, Giulio Conte, Krzysztof S Gołba, Jolanta Biernat, Jacek Wilczek, Magdalena Dąbrowska, Simone Pezzuto, Tiziano Moccetti, Rolf Krause, Wojciech Wojakowski, Frits W Prinzen, Angelo Auricchio

Research output: Contribution to journalArticlepeer-review

8 Citations (Scopus)

Abstract

AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar.

METHODS AND RESULTS: Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02].

CONCLUSION: Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.

Bibliographical note

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author(s) 2020. For permissions, please email: journals.permissions@oup.com.

Keywords

  • Cardiac Resynchronization Therapy
  • Cicatrix/diagnostic imaging
  • Heart Failure/diagnostic imaging
  • Heart Ventricles/diagnostic imaging
  • Humans
  • Magnetic Resonance Imaging, Cine

Fingerprint

Dive into the research topics of 'The influence of scar on the spatio-temporal relationship between electrical and mechanical activation in heart failure patients'. Together they form a unique fingerprint.

Cite this