Projecten per jaar
Samenvatting
A new type of microfluidic flow distributor (referred to as the mixed mode or MM-distributor) is proposed. Its performance characteristics are determined using computational fluid dynamics (CFD), both in the absence and the presence of clogging, which is an important problem in microfluidic systems. A comparison is made with two existing, well-performing distributor types: the bifurcating (BF) distributor and an optimized diverging distributor, the so-called radially interconnected (RI) distributor.
It was found that, in the absence of clogging, the MM-distributor produces only a little more dispersion than the bifurcating (BF) distributor, but much less than the radially interconnected (RI) distributor. The dispersion in an MM-distributor also follows a similar dependency on its width (power congruent to 2) as the BF-distributor. The dispersion in the RI-distributor on the other hand displays a very disadvantageous 4th-order dependency on its width, prohibiting its use to distribute the flow across wide beds (order of millimeters or centimeters). These observations hold independently of the flow rate.
With increasing degree of clogging, the MM-distributor rapidly becomes advantageous over the BF distributor, owing to the fluid contact zones that are provided after each bifurcation step. This means that overall, and when the occurrence of clogging cannot be excluded, the MM-type distributor seems to offer the best possible compromise between the ability to cope with local clogging events and the dispersion in the absence of clogging. (C) 2018 Elsevier B.V. All rights reserved.
It was found that, in the absence of clogging, the MM-distributor produces only a little more dispersion than the bifurcating (BF) distributor, but much less than the radially interconnected (RI) distributor. The dispersion in an MM-distributor also follows a similar dependency on its width (power congruent to 2) as the BF-distributor. The dispersion in the RI-distributor on the other hand displays a very disadvantageous 4th-order dependency on its width, prohibiting its use to distribute the flow across wide beds (order of millimeters or centimeters). These observations hold independently of the flow rate.
With increasing degree of clogging, the MM-distributor rapidly becomes advantageous over the BF distributor, owing to the fluid contact zones that are provided after each bifurcation step. This means that overall, and when the occurrence of clogging cannot be excluded, the MM-type distributor seems to offer the best possible compromise between the ability to cope with local clogging events and the dispersion in the absence of clogging. (C) 2018 Elsevier B.V. All rights reserved.
Originele taal-2 | English |
---|---|
Pagina's (van-tot) | 75-82 |
Aantal pagina's | 8 |
Tijdschrift | Journal of Chromatography A |
Volume | 1537 |
DOI's | |
Status | Published - 16 feb 2018 |
Vingerafdruk
Duik in de onderzoeksthema's van 'A microfluidic distributor combining minimal volume, minimal dispersion and minimal sensitivity to clogging'. Samen vormen ze een unieke vingerafdruk.Projecten
- 1 Afgelopen
-
SRP6: SRP (Zwaartepunt): exploitatie van de voordelen van de Orde in Opsluiting voor een groenere chemie
Desmet, G., Denayer, J., Denayer, J., Desmet, G. & Denayer, J.
1/11/12 → 31/10/22
Project: Fundamenteel