Samenvatting
Aims: The aim of this paper is to report a method of atherosclerotic plaque tissue characterisation based on pattern recognition and assess its accuracy under conditions of potential clinical relevance.
Methods and results: Excised saline infused human arteries were imaged using IVUS with RE acquisition. 40% of the vessels were re-imaged with human blood infusion. A database of similar to 12000 image regions-of-interest (ROIs) of histologically established types was used to design a pattern recognition algorithm to predict the tissue type of a given ROI by comparing its RE-spectrum against the database, and also to estimate the confidence of prediction. Ex vivo validation demonstrated accuracies at the highest level of confidence as: 97%, 98%, 95%, and 98% for necrotic, lipidic, fibrotic and calcified regions respectively. Good agreement with histology was shown in an in vivo swine animal model.
Conclusions: Ex vivo validation demonstrated the ability to characterise plaque tissue using an IVUS+RF system and a method incorporating (1) full spectral information (2) spectral similarity (3) estimating confidence of characterisation and, (4) ability to characterise plaque imaged through blood. Promising results were demonstrated in a live animal model. This approach may have potential for accurate and reproducible plaque characterisation in vivo.
Methods and results: Excised saline infused human arteries were imaged using IVUS with RE acquisition. 40% of the vessels were re-imaged with human blood infusion. A database of similar to 12000 image regions-of-interest (ROIs) of histologically established types was used to design a pattern recognition algorithm to predict the tissue type of a given ROI by comparing its RE-spectrum against the database, and also to estimate the confidence of prediction. Ex vivo validation demonstrated accuracies at the highest level of confidence as: 97%, 98%, 95%, and 98% for necrotic, lipidic, fibrotic and calcified regions respectively. Good agreement with histology was shown in an in vivo swine animal model.
Conclusions: Ex vivo validation demonstrated the ability to characterise plaque tissue using an IVUS+RF system and a method incorporating (1) full spectral information (2) spectral similarity (3) estimating confidence of characterisation and, (4) ability to characterise plaque imaged through blood. Promising results were demonstrated in a live animal model. This approach may have potential for accurate and reproducible plaque characterisation in vivo.
| Originele taal-2 | English |
|---|---|
| Pagina's (van-tot) | 133-139 |
| Aantal pagina's | 7 |
| Tijdschrift | EuroIntervention |
| Volume | 5 |
| Nummer van het tijdschrift | 1 |
| Status | Published - mei 2009 |
Vingerafdruk
Duik in de onderzoeksthema's van 'Characterisation of atherosclerotic plaque by spectral similarity of radiofrequency intravascular ultrasound signals'. Samen vormen ze een unieke vingerafdruk.Citeer dit
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver