Comparison of Pulmonary Vein Isolation Using Cryoballoon Versus Conventional Radiofrequency for Paroxysmal Atrial Fibrillation.

G. Mugnai, Jean-Baptiste Chierchia, Carlo De Asmundis, J. Sieira, G. Conte, Lucio Capulzini, Kristel Wauters, M. Rodriguez-Mañero, G. Di Giovanni, G. Baltogiannis, G. Ciconte, Y. Saitoh, J. Julia, Pedro Brugada

Onderzoeksoutput: Articlepeer review

81 Citaten (Scopus)

Samenvatting

The aim of this study was to compare the results of pulmonary vein isolation using conventional irrigated radiofrequency (RF) approach versus the cryoballoon (CB) ablation. From January 2008 to December 2011, a total of 426 patients with drug-resistant symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation as the index procedure by conventional manual RF or CB ablation at our center. A final population of 396 patients was considered for analysis and divided into 2 groups: conventional RF ablation (n = 260) and CB ablation (n = 136). At a mean follow-up of 23 ± 13 months (median 27, range 4 to 68), the success rate for RF ablation group was 57.3% (149 patients) and was 63.2% (86 patients) for cryoablation group (p = 0.25). Procedural times were significantly shorter in the cryoablation group (192 ± 49 vs 112 ± 58 minutes, p
Originele taal-2English
Pagina's (van-tot)1509-1513
Aantal pagina's5
TijdschriftThe American Journal of Cardiology
Volume113
Nummer van het tijdschrift9
StatusPublished - 1 mei 2014