Effect of a plasma sodium biofeedback system applied to HFR on the intradialytic cardiovascular stability. Results from a randomized controlled study

  • Francesco Locatelli
  • , Sergio Stefoni
  • , Thierry Petitclerc
  • , Luigi Coli
  • , Salvatore Di Filippo
  • , Simeone Andrulli
  • , Christine Fumeron
  • , Giovanni Maria Frasca
  • , Sibilla Sagripanti
  • , Silvana Savoldi
  • , Andrea Serra
  • , Carmine Stallone
  • , Filippo Aucella
  • , Antonio Gesuete
  • , Antonio Scarlatella
  • , Francesco Quarello
  • , Paola Mesiano
  • , Peter Ahrenholz
  • , Roland Winkler
  • , Lise Mandart
  • Joan Fort, Christian Tielemans, Carlo Navino

Onderzoeksoutput: Article › peer review

27 Citaten (Scopus)

Samenvatting

Background
Intradialytic hypotension (IDH) is still a major clinical problem for haemodialysis (HD) patients. Haemodiafiltration (HDF) has been shown to be able to reduce the incidence of IDH.

Methods
Fifty patients were enrolled in a prospective, randomized, crossover international study focussed on a variant of traditional HDF, haemofiltration with endogenous reinfusion (HFR). After a 1-month run-in period on HFR, the patients were randomized to two treatments of 2 months duration: HFR (Period A) or HFR-Aequilibrium (Period B), followed by a 1-month HFR wash-out period and then switched to the other treatment. HFR-Aequilibrium (HFR-Aeq) is an evolution of the haemofiltration with endogenous reinfusion (HFR) dialysis therapy, with dialysate sodium concentration and ultrafiltration rate profiles elaborated by an automated procedure. The primary end point was the frequency of IDH.

Results
Symptomatic hypotension episodes were significantly lower on HFR-Aeq versus HFR (23 ± 3 versus 31 ± 4% of sessions, respectively, P l= l0.03), as was the per cent of clinical interventions (17 ± 3% of sessions with almost one intervention on HFR-Aeq versus 22 ± 2% on HFR, P
Conclusions
HFR-Aeq, a profiled dialysis supported by the Natrium sensor for the pre-dialysis Na+ measure, can significantly reduce the burden of IDH. This could have an important impact in every day dialysis practice.
Originele taal-2English
Pagina's (van-tot)3935-3942
TijdschriftNephrology Dialysis Transplantation
Volume27
Nummer van het tijdschrift10
StatusPublished - 4 mei 2011