Samenvatting
This paper aims at assessing the impact of retrofitting an existing, 730 MWe, coal-fired power plant into a biomass-fired combined heat and power (CHP) plant on its energetic and exergetic performances. A comprehensive thermodynamic model of the power plant was developed and valitdated against field data, resulting in less than 1% deviation between the model and the measurements for the main process parameters. The validated model was then used to predict the behaviour of the biomass CHP after retrofitting. The modelled CHP unit is coupled to a steam-explosion biomass upgrading plant, a biorefinery process, and a high-temperature heat network. 13 scenarios were
studied. At constant boiler load, delivering heat to the considered heat clients can increase the total energy efficiency of the plant from 44% (electricity only) to 64%, while the total exergy efficiency decreases from 39% to 35%. A total energy efficiency of 67% could be reached by lowering the network temperature from 120 ◦C to 70 ◦C. Identifying the needed heat clients could, however, represent a limiting factor to reach such high efficiencies. For a constant power demand, increasing the boiler load from 80 to 100% in order to provide additional heat makes the total energy efficiency increase from 43% to 55%, while the total exergy efficiency decreases from 39% to 36%.
studied. At constant boiler load, delivering heat to the considered heat clients can increase the total energy efficiency of the plant from 44% (electricity only) to 64%, while the total exergy efficiency decreases from 39% to 35%. A total energy efficiency of 67% could be reached by lowering the network temperature from 120 ◦C to 70 ◦C. Identifying the needed heat clients could, however, represent a limiting factor to reach such high efficiencies. For a constant power demand, increasing the boiler load from 80 to 100% in order to provide additional heat makes the total energy efficiency increase from 43% to 55%, while the total exergy efficiency decreases from 39% to 36%.
| Originele taal-2 | English |
|---|---|
| Artikelnummer | 7720 |
| Aantal pagina's | 15 |
| Tijdschrift | Energies |
| Volume | 14 |
| Nummer van het tijdschrift | 22 |
| DOI's | |
| Status | Published - nov. 2021 |
Bibliografische nota
Funding Information:Funding: This research was funded by European Union’s Horizon 2020 research and innovation program grant number 818349.
Funding Information:
Acknowledgments: The results of the work presented in this paper were generated within the EU-H2020 project “Cost-effective transformation of a highly-efficient advanced thermal ultra-supercritical coal-fired power plant into a CHP by retrofitting and integrating an ARBAFLAME biomass upgrading process”, with the acronym ARBAHEAT. This project has received funding from the European Union’s Horizon 2020 research and innovation program under grant agreement No. 818349.
Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
Vingerafdruk
Duik in de onderzoeksthema's van 'Energetic and Exergetic Performances of a Retrofitted, Large-Scale, Biomass-Fired CHP Coupled to a Steam-Explosion Biomass Upgrading Plant, a Biorefinery Process and a High-Temperature Heat Network'. Samen vormen ze een unieke vingerafdruk.Projecten
- 1 Afgelopen
Citeer dit
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver