Revealing the Mixed Mode Failure Under Pull-Out of Masonry Retrofitted by Textile Reinforced Mortar (TRM)

David Martin Linn III, Dimitrios Angelis, Eleni Tsangouri

Onderzoeksoutput: Conference paper

Samenvatting

The performance of TRM retrofit solutions for damaged masonry structural elements is evaluated in this study using pull-out testing procedure recommended by the RILEM TC 250-CSM. The parametric analysis (textile/interface surface treatment/setup configuration) is designed to trigger different failure modes during testing and the damage progress is continuously and online tracked by an integrated monitoring system that combines the acoustic emission and digital image correlation techniques. Based on inspection outcome and the loaddisplacement curves obtained, it is evident that different damage modes occur simultaneously while the effect of boundary conditions and interface surface treatment is highlighted.
Originele taal-2English
Titel13th International Symposium on Ferrocement and Thin Fiber Reinforced Inorganic Matrices
RedacteurenAmir Si Larbi, Hani Nassif
Plaats van productieLyon
Uitgeverij Ecole Centrale de Lyon (ENISE-ECL)
Pagina's312-317
Aantal pagina's7
StatusPublished - 2021
EvenementTHE 13TH INTERNATIONAL SYMPOSIUM ON FERROCEMENT AND THIN FIBER REINFORCED INORGANIC MATRICES - Lyon, France
Duur: 21 jun 202123 jun 2021
https://ferro13.sciencesconf.org/

Conference

ConferenceTHE 13TH INTERNATIONAL SYMPOSIUM ON FERROCEMENT AND THIN FIBER REINFORCED INORGANIC MATRICES
LandFrance
StadLyon
Periode21/06/2123/06/21
Internet adres

Citeer dit