TY - JOUR
T1 - Stationary-phase optimized selectivity in supercritical fluid chromatography using a customized Phase OPtimized Liquid Chromatography kit
T2 - comparison of different prediction approaches
AU - Grooten, Yasmine
AU - Riasová, Petra
AU - Salsinha, Inês
AU - Mangelings, Debby
AU - Vander Heyden, Yvan
N1 - Funding Information:
Y.G. is funded by a Ph. D. fellowship of the Research Foundation – Flanders (FWO) (grant 11D3518N). P.R. is funded by grant project SVV 260 548.
Publisher Copyright:
© 2020, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2020/9/1
Y1 - 2020/9/1
N2 - The use of stationary-phase optimized selectivity in liquid chromatography (SOS-LC) was shown to be successful for HPLC to analyze complex mixtures using a Phase OPtimized Liquid Chromatography (POPLC) kit. This commercial kit contains five stationary-phase types of varying lengths, which can be coupled to offer an improved separation of compounds. Recently, stationary-phase optimized selectivity supercritical fluid chromatography (SOS-SFC) has been introduced, transferring the methodology to SFC. In this study, the applicability of a customized POPLC expert kit for isocratic SFC runs was explored. Five stationary-phase chemistries were selected as potentially most suitable for achiral separations of polar compounds: aminopropyl (amino), cyanopropyl (CN), diol, ethylpyridine (EP), and silica. The retention factors (k) on the individual stationary phases were used for the prediction of the best stationary-phase combination, based on the POPLC algorithm (via the included software). As an alternative, the best column combination was predicted using multiple linear regression (MLR) models on the results obtained from a simplex centroid mixture design with only three stationary-phase types (amino, silica, and EP). A third approach applied the isocratic POPLC algorithm on the same three stationary-phase data. The proposed combinations were assembled and tested. The predicted and experimental retention factors were compared. The predictions based on the POPLC algorithm provided a stationary phase showing a complete separation of the mixture. The stationary phase suggested by the MLR models, on the other hand, showed co-elution of two compounds, due to an unexpected experimental retention shift. Overall, the customized POPLC kit showed good potential to be applied in SFC. Graphical abstract.
AB - The use of stationary-phase optimized selectivity in liquid chromatography (SOS-LC) was shown to be successful for HPLC to analyze complex mixtures using a Phase OPtimized Liquid Chromatography (POPLC) kit. This commercial kit contains five stationary-phase types of varying lengths, which can be coupled to offer an improved separation of compounds. Recently, stationary-phase optimized selectivity supercritical fluid chromatography (SOS-SFC) has been introduced, transferring the methodology to SFC. In this study, the applicability of a customized POPLC expert kit for isocratic SFC runs was explored. Five stationary-phase chemistries were selected as potentially most suitable for achiral separations of polar compounds: aminopropyl (amino), cyanopropyl (CN), diol, ethylpyridine (EP), and silica. The retention factors (k) on the individual stationary phases were used for the prediction of the best stationary-phase combination, based on the POPLC algorithm (via the included software). As an alternative, the best column combination was predicted using multiple linear regression (MLR) models on the results obtained from a simplex centroid mixture design with only three stationary-phase types (amino, silica, and EP). A third approach applied the isocratic POPLC algorithm on the same three stationary-phase data. The proposed combinations were assembled and tested. The predicted and experimental retention factors were compared. The predictions based on the POPLC algorithm provided a stationary phase showing a complete separation of the mixture. The stationary phase suggested by the MLR models, on the other hand, showed co-elution of two compounds, due to an unexpected experimental retention shift. Overall, the customized POPLC kit showed good potential to be applied in SFC. Graphical abstract.
UR - http://www.scopus.com/inward/record.url?scp=85086224799&partnerID=8YFLogxK
U2 - 10.1007/s00216-020-02739-w
DO - 10.1007/s00216-020-02739-w
M3 - Article
C2 - 32529302
VL - 412
SP - 6553
EP - 6565
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
SN - 1618-2642
IS - 24
ER -