T1 - The fetal fibronectin test: 25 years after its development, what is the evidence regarding its clinical utility? A systematic review and meta-analysis
AU - Faron, Gilles
AU - Balepa, Lisa
AU - Parra, Jose
AU - Fils, Jean-Francois
AU - Gucciardo, Leonardo
PY - 2020/2/1
Y1 - 2020/2/1
N2 - Background: The identification of women at risk for preterm birth should allow interventions which could improve neonatal outcome. Fetal fibronectin, a glycoprotein which acts normally as glue between decidua and amniotic membranes could be a good marker of impending labour when its concentration in cervicovaginal secretions between 22 and 36 weeks of gestation is ≥50 ng/mL. Many authors worldwide have tested this marker with many different methodologies and clinical settings, but conclusions about its clinical use are mixed. It is time for a comprehensive update through a systematic review and meta-analysis. Methods: We searched PubMed, Cochrane Library, and Embase, supplemented by manual search of bibliographies of known primary and review articles, international conference papers, and contact with experts from 1–1990 to 2–2018. We have selected all type of studies involving fetal fibronectin test accuracy for preterm delivery. Two authors independently extracted data about study characteristics and quality from identified publications. Contingency tables were constructed. Reference standards were preterm delivery before 37, 36, 35, 34, and 32 weeks, within 28, 21, 14, or 7 d and within 48 h. Data were pooled to produce summary likelihood ratios for positive and negative tests results. Results: One hundred and ninety-three primary studies were identified allowing analysis of 53 subgroups. In all settings, none of the summary likelihood ratios were >10 or <0.1, thus indicating moderate prediction, particularly in asymptomatic women and in multiple gestations. Conclusions: The fetal fibronectin test should not be used as a screening test for asymptomatic women. For high-risk asymptomatic women, and especially for women with multiple pregnancies, the performance of the fetal fibronectin test was also too low to be clinically relevant. Consensual use as a diagnostic tool for women with suspected preterm labor, the best use policy probably still depends on local contingencies, future cost-effectiveness analysis, and comparison with other more recent available biochemical markers.
AB - Background: The identification of women at risk for preterm birth should allow interventions which could improve neonatal outcome. Fetal fibronectin, a glycoprotein which acts normally as glue between decidua and amniotic membranes could be a good marker of impending labour when its concentration in cervicovaginal secretions between 22 and 36 weeks of gestation is ≥50 ng/mL. Many authors worldwide have tested this marker with many different methodologies and clinical settings, but conclusions about its clinical use are mixed. It is time for a comprehensive update through a systematic review and meta-analysis. Methods: We searched PubMed, Cochrane Library, and Embase, supplemented by manual search of bibliographies of known primary and review articles, international conference papers, and contact with experts from 1–1990 to 2–2018. We have selected all type of studies involving fetal fibronectin test accuracy for preterm delivery. Two authors independently extracted data about study characteristics and quality from identified publications. Contingency tables were constructed. Reference standards were preterm delivery before 37, 36, 35, 34, and 32 weeks, within 28, 21, 14, or 7 d and within 48 h. Data were pooled to produce summary likelihood ratios for positive and negative tests results. Results: One hundred and ninety-three primary studies were identified allowing analysis of 53 subgroups. In all settings, none of the summary likelihood ratios were >10 or <0.1, thus indicating moderate prediction, particularly in asymptomatic women and in multiple gestations. Conclusions: The fetal fibronectin test should not be used as a screening test for asymptomatic women. For high-risk asymptomatic women, and especially for women with multiple pregnancies, the performance of the fetal fibronectin test was also too low to be clinically relevant. Consensual use as a diagnostic tool for women with suspected preterm labor, the best use policy probably still depends on local contingencies, future cost-effectiveness analysis, and comparison with other more recent available biochemical markers.
KW - Fetal fibronectin test
KW - meta-analysis
KW - preterm delivery
KW - preterm labor
KW - systematic review
UR - http://www.scopus.com/inward/record.url?scp=85058982860&partnerID=8YFLogxK
U2 - 10.1080/14767058.2018.1491031
DO - 10.1080/14767058.2018.1491031
M3 - Scientific review
VL - 33
SP - 493
EP - 523
JO - Journal of Maternal-Fetal and Neonatal Medicine
JF - Journal of Maternal-Fetal and Neonatal Medicine
SN - 1476-7058
IS - 3
ER -